[. . . ] DLPTM PROJECTOR MODEL XD8100U User Manual XD8100 This User Manual is important to you. Please read it before using your projector. U CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. CAUTION: TO PREVENT ELECTRIC SHOCK, DO NOT USE THIS (POLARIZED) PLUG WITH AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE. NOTE: SINCE THIS PROJECTOR IS PLUGGABLE EQUIPMENT, THE SOCKET-OUTLET SHALL BE INSTALLED NEAR THE EQUIPMENT AND SHALL BE EASILY ACCESSIBLE. If you use another power supply cord, it may cause interference with radio and television reception. DO NOT LOOK DIRECTLY INTO THE LENS WHEN THE PROJECTOR IS IN THE POWER ON MODE. [. . . ] However, DEFAULT GATEWAY is not set as factory default, and cannot be displayed. (See page 51. ) Select this setting when using ProjectorView Global+ or ProjectorView. (See pages 51 and 58. ) Select this setting when using the controller or software of Crestron Electronics, Inc. (See page 52. ) EN-40 Menu operation (continued) INFORMATION menu opt. 1 2 INFORMATION LAMP 1 TIME (LOW) LAMP 2 TIME (LOW) NEXT LAMP RELAY FILTER TIME SERIAL NUMBER INPUT RESOLUTION VERTICAL FREQUENCY HORIZONTAL FREQUENCY RGB H V ****H ****H *D **H *****H / ****TIMES ********. . . COMPUTER1 1024 x 768 60. 00 Hz 48. 36 kHz 5WIRE SYNC. TYPE ITEM LAMP 1 TIME (LOW) LAMP 2 TIME (LOW) NEXT LAMP RELAY FILTER TIME SERIAL NUMBER INPUT RESOLUTION VERTICAL FREQUENCY HORIZONTAL FREQUENCY SYNC. TYPE · DESCRIPTION This item shows the lamp operation time calculated based on that the LAMP MODE of LAMP 1 is LOW. · When the LAMP MODE is STANDARD, this item shows a longer lamp operating time than the actual time. · When the lamp operating time is 0 to 10 hours, "0H" is displayed. The lamp operating time exceeding 10 hours is indicated by the actual hours. · When the lamp operating time reaches 3000 hours, the bar turns to yellow. · The icon displayed to the right of the bar shows the lamp status. Yellow: On, Red: End of lamp life or error such as illumination failure, Black: Off This item shows the lamp operation time calculated based on that the LAMP MODE of LAMP 2 is LOW. · When the LAMP MODE is STANDARD, this item shows a longer lamp operating time than the actual time. · When the lamp operating time is 0 to 10 hours, "0H" is displayed. The lamp operating time exceeding 10 hours is indicated by the actual hours. · When the lamp operating time reaches 3000 hours, the bar turns to yellow. · The icon displayed to the right of the bar shows the lamp status. Yellow: On, Red: End of lamp life or error such as illumination failure, Black: Off The next lamp relay time is displayed. Indicates the name of the terminal to which the currently projected video signal is being input. Indicates the vertical frequency of the currently projected video signal. Indicates the horizontal frequency of the currently projected video signal. Indicates the type of the sync signal for the currently projected video signal. NEXT LAMP RELAY isn't displayed when LAMP RELAY is OFF or LAMP SELECT is LAMP 1 or LAMP 2 in the INSTALLATION 1 menu. EN-41 Adjusting projected images To adjust the brightness (CONTRAST and BRIGHTNESS): You can make adjustments for the brightness of the projected image using the menu. [. . . ] Abnormal To illuminate the failed lamp again when either Blinking orange condition indicator blinks, turn off the power and wait until the indicator stops blinking and then press the POWER button. If the light source lamp doesn't illuminate even after you perform the above operation several times, unplug the power cord from the wall outlet and contact your dealer. *4: When LAMP MODE is set to STANDARD, this duration will be shorted up to 2000 hours. Lamp operation time warning. (Total lamp operation time reached 4000 hours*3*4. ) The protection circuit is working or the lamp is in an abnormal condition. [. . . ]